CBVVF - MARINE CLEANER & DEGREASER (AEROSOL), 06019

  • MSDS: CBVVF
  • Manufacturer: CRC CHEMICALS
  • Product Name: MARINE CLEANER & DEGREASER (AEROSOL), 06019
  • National Stock Number: 6850-00N028771
Product Identification

Product ID:MARINE CLEANER & DEGREASER (AEROSOL), 06019
MSDS Date:06/01/1989
FSC:6850
NIIN:00N028771
MSDS Number: CBVVF

Responsible Party
CRC CHEMICALS
885 LOUIS DR
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: ALLEN B REED

Cage: CRCCE

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 89.7%

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM/450STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TERT-BUTYL ALCOHOL (SARA 313)

CAS: 75-65-0

RTECS: EO1925000

Fraction By Weight: 1.5%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM


BUTANE, 1,2-EPOXY-; (1,2-BUTYLENE OXIDE) (SARA 313)

CAS: 106-88-7

RTECS: EK3675000

Fraction By Weight: 4.8%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


METHANE, DIMETHOXY-; (DIMETHOXYMETHANE)

CAS: 109-87-5

RTECS: PA8750000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 4.0%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: HEADACHES,
DIZZINESS, ANESTHESIA, UNCONSCIOUSNESS. EYES: CAUSES PAIN AND SOME
IRRITATION. SKIN: IRRITATION ON REPEATED EXPOSURES. CHRONIC:
REPEATED OVEREXPOSURE MAY CAUSE LIVER AND KIDNEY EFFECTS.
CHOLOROCARBON MATERIALSHAVE PRODUCED SENSITIZATION OF THE
MYOCARDIUM TO EPINEPHRINE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: IN LABORATORY ANIMALS AND COULD HAVE
A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY
BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY OR CHRONICALLY EX POSED TO CHOLOROCARBONS .
Medical Cond Aggravated by Exposure:HIGH LEVELS (8000 PPM +) OF VAPOR
MAY CAUSE CARDIAC ARRHYTHMIAS.

First Aid

First Aid:IF SYMPTOMS PERSIST, CALL MD. INHALATION: REMOVE TO FRESH
AIR. APPLY ARTIFICIAL RESPIRATION IF NECESSARY. EYES: FLUSH WITH
LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN: REMOVE
CONTAMINATED CLO THING. WASH EXPOSED AREA WITH SOAP AND WATER.
INGESTION: DO NOT INDUCE VOMITING. CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Lower Limits:6%
Upper Limits:16.7%
Extinguishing Media:USE WATER, FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSUDE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AEROSOL CANS MAY EXPLODE IF THEIR
TEMPERATURE EXCEEDS 130F. THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:USUALLY NOT A PROBLEM WITH AEROSOLS. AREA
SHOULD BE VENTILATED AND ABSORBENT USED TO PICK UP EXCESS MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE. AVOID SKIN
CONT/BRTHG OF VAPS. SINCE VAPS HVR/AIR, AEROSOLS SHOULD NOT BE
USED IN CONFINED AREAS/LOW SOPTS W/OUT ADEQ VENT.
Other Precautions:IF VAPS ARE SUSPECTED IN LOW AREA, DO NOT ENTER
UNLESS SPECIAL BRTHG APPARATUS IS USED & AN OBSERVER IS PRESENT FOR
ASSIST. KEEP AEROSOLS AWAY FROM HEAT. NO SMOKING IN AREA OF USE. DO
NOT USE IN GENER AL VICINITY OF ARC WELDING, (SUP DAT)

Exposure Controls

Respiratory Protection:ABOVE TLV USE NIOSH/MSHA APPROVED SCBA (AIR MAKS
OR VAPOR MASK).
Ventilation:MAINTAIN VAPOR CONCENTRATION BELOW TLV. USE MECHANICAL
MEANS IF NECESSARY.
Protective Gloves:SOLVENT-RESISTANT.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:NOT NORMALLY REQUIRED FOR AEROSOL PRODUCT
USAGE. EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC: OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV RADIATION MAY
CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Chemical Properties

Boiling Pt:B.P. Text:2F,-17C
Vapor Pres:100 @ 20C
Vapor Density:4.55
Spec Gravity:1.293
Evaporation Rate & Reference:RAPID
Solubility in Water:SLIGHTLY SOLUBLE
Appearance and Odor:COLORLESS LIQUID, WITH IRRITATING ODOR AT HIGH
CONCENTRATIONS
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS, OR CONTACT WITH ALUMINUM AND/OR
ZINC POWDER.
Stability Condition to Avoid:AVOID EXPOSURE TO OPEN FLAMES, ARCS, AND
HIGH TEMPERATURES.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, CHLORINE AND SOME
PHOSGENE.

Disposal

Waste Disposal Methods:DISCARDED FULL CANS OR PARTIALLY FILLED CANS ARE
CONSIDERED HAZARDOUS WASTE. DISPOSE OF IN CONFORMANCE WITH LOCAL,
STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.